Cell Constant | 0.1 |
Color | Black |
Maximum Pressure | 5 bar |
Number of poles | 2 pole |
I Deal In | New Only |
Cell constant | K = 0.01 |
Usage/Application | Industrial |
Cabinet | Flame retardant grade Plastic enclosure |
Display | 3 1/2 Digit LCD |
Size | Front Fascia - 96mm x 96mm, Cut Out - 92mm x 92mm |
Range | a. 199.9μs b. 1999μs c. 19.99 ms d. 199.9 ms The range is selectable from the rear and can be calibrated by ‘Cell Adj’ at the front for individual range. |
Resolution | 0.1μs to 0.1ms depending on range selected. |
Accuracy | ± 0.5% of Full-Scale ± 1 Least Significant Digit. |
Sensor | Contact Type’ with Cell Constant 1.0 |
Temperature | Uses PT100, precision temperature sensor (External). |
Compensation | The Compensation is internally set at 2% per ˚C NOTE: If PT100 is not available, then fix a simulated resistance of PT100 @ 25˚C approx. 110Ω. Instrument will not work otherwise. |
Limit Setting | Using 2 Nos. 10 turn precision trimpots on front panel to set the High/Low Limi |
Control Output | Two set of NO-P-NC, 5 Amps potential free Relay Contacts. a. Relay 1 (High) ON, for Conductivity > High Limit b. Relay 2 (Low) ON, for Conductivity < Low Limit |
Recorder Output | 0-2V for the selected range Max. current output capability 2mA |
Supply | 110V AC/220V AC ± 15% Internally selectable |
Material | Mild Steel |
Conductivity Range | 150 mS/cm |
TDS Range | 2000 ppm |
Display | 3 1/2 Digit 13mm High, RED LED. |
Temperature Compensation | Automatic Using External PT-100 Sensor |
*Your information is safe with us.
Material | Stainless Steel |
Conductivity Range | 100 mS/cm |
Brand | Countronics |
Size | 198mm x 89mm x 60mm (LxWxH) - with flange |
Ranges | 19.99ms - 199.9ms |
(Factory Set) | 1999 µs 19.99ms 199.9µs 1999 µs 19.99µs 199.9µs (0.1Cell) (1.0 Cell) |
Accuracy | ± 0.5% of F.S. ± 1 LSD |
Sensor | ‘Contact type’ with Cell constant 0.1 or 1.0. |
Temp. | Uses PT-100, precision temperature Comp. sensor (external). The compensation is internally set at 2%/˚C |
Supply | 220V AC ± 15% @ 50Hz/60Hz |
Conductivity Range | 100 mS/cm |
Display Type | Digital |
Enclosure | Plastic (ABS). Size - 272x192x90mm |
Weight | 900 g |
Display | 2 line large alphanumeric display with back light illumination |
Ranges | pH: 0.00 to 14.00 pH ORP: 0-2000mV Conductivity: 19.99ms/1999µs/199.9µs/19.99µs in 0.1 Cell Constant 199.9ms/19.99ms/1999µs/199.9µs in 1.0 Cell Constant TDS: 0-1999ppm |
Resolution | pH: 0.01pH ORP: 1mV Conductivity: 0.01ms or 0.01µs depending on range & Cell factor TDS: 1ppm |
Auto Temp. Comp. | 0-100˚C using PT100 external sensor for pH and Conductivity |
Manual Temp. Comp. | Settable from front panel from 0-100.0˚C for pH and Conductivity |
pH Calibration | 2 Point calibration with auto buffer recognition. Buffers recognized: 4.00, 7.00, 9.00, 10.00 pH |
Conductivity Calibration | Digital calibration by factor multiplication from 0.75-1.25 |
Accuracy | 0.5% ± 1 Digit |
Supply | 220V AC ±10% @ 50Hz |
Color | Black |
Power | 12 to 80 VDC |
Process temperature | Max 200 degree celsius |
Process pressure | Max. 3 bar |
Country of Origin | Made in India |
Product Specification: