New Delhi, Delhi
GST No. 07AAEPA2927Q1ZK
Call 08043885108 85% Response Rate
Send Enquiry
Product Brochure
| Usage/Application | Industrial |
| Display Type | Digital |
| Material | Stainless Steel |
| Grade | A |
| I Deal In | New Only |
| Country of Origin | Made in India |
| Display | 2 Line alphanumeric display with back light illumination 4 digit for Load in KN , 3 digit for Pace Rate in KN/sec Peak/Normal indication |
| Range | a. Load : 0.1KN to 6000KN b. Set Load (Limit) : 0.1KN to 6000KN c. Sample Area : 0.1cm2 to 999.9cm2 |
| Accuracy | ±0.1% of Full Scale ± 1 digit |
| Input | From 2 wire loop transmitter giving 4-20mA output 4-20mA input => 0 – Range |
| Relay Logic | When Actual Load ≥ Set Load Limit relay switches On. |
| Normal/Peak Mode | Selectable from front panel with indication of mode |
| Serial Output | Formatted RS-232 output to interface for logging using Hyperterminal |
| Real Time Clock | Date and Time setting with internal battery backup |
| Sample No | Auto increment with resetting option |
| Peak Detection | Peak hold is resettable from front Reset Switch or by parallel rear |
Additional Information:
View Complete details
Product Brochure
| Usage/Application | Industrial |
| Display Type | Digital |
| Material | Stainless Steel |
| Color | Black |
| I Deal In | New Only |
| Country of Origin | Made in India |
Specification :
Display | 4 Digit 0.56” 7 segment Red LED display for Load (KN) |
Range | Load: 1KN to Range Displacement: 0.1mm to 9999 |
Accuracy | ±0.1% of Full Scale ± 1 digit |
Input | From 2 wire loop transmitter giving 4-20mA output 4-20mA input => 0 - Range |
Relay Logic | When Actual Load ≥ Set Load Limit relay switches On. |
Normal/Peak Mode | Selectable from front panel with LED indication of mode |
Peak Read | Last 9 peaks can be recalled with facility to reset memory |
Peak Detection | Peak hold resettable by front Reset Switch or by parallel rear external contact |
Tare Facility (Zero) | Digital Tare using front panel Tare switch up to a maximum of 50KN (for removing initial offset error) |
Memory | Non-volatile EEPROM to save settings |
Configuration Lock | On rear terminals to prevent unauthorized/accidental alteration of Range using front switches |
Supply | 220V AC ± 15% 50/60Hz |
Dimensions | Front Fascia: 96mm x 192mm Cut Out : 92mm x 188mm |
Additional Information:
View Complete details
Product Brochure
| Usage/Application | Industrial |
| Type | Timer |
| Input | Voltage |
| Voltage | 220V AC |
| Frequency | 50 Hz |
We are offering quality product Pace Rate Controller from Delhi India.
Pace Rate ControllerFeatures :
| Display | 2 Line alphanumeric display with back light illumination 4 digit for Load in KN , 3 digit for Pace Rate in KN/sec Peak/Normal indication |
| Range | a. Load: 0.1KN to 6000KN b. Set Load (Limit) : 0.1KN to 6000KN c. Sample Area : 0.1cm2 to 999.9cm2 |
| Accuracy | ±0.1% of Full Scale ± 1 digit |
| Input | From 2 wire loop transmitter giving 4-20mA output 4-20mA input => 0 - Range |
| Relay Logic | When Actual Load ≥ Set Load Limit relay switches On. |
| Normal/Peak Mode | Selectable from front panel with indication of mode |
| Serial Output | Formatted RS-232 output to interface for logging using Hyperterminal |
| Real Time Clock | Date and Time setting with internal battery backup |
| Sample No. | Auto increment with resetting option |
| Peak Detection | Peak hold is resettable from front Reset Switch or by parallel rear external contact |
| Tare Facility (Zero) | Digital Tare using front panel Tare switch up to a maximum of 50KN (for removing initial offset error) |
| Memory | Non-volatile EEPROM to save settings |
| Configuration Lock | On rear terminals to prevent unauthorized/accidental alteration of Range using front switches |
| Supply | 220V AC ± 15% 50/60Hz |
| Dimensions | Front Fascia: 96mm x 192mm Cut Out : 92mm x 188mm |
Additional Information:
View Complete details
Product Brochure
| Usage/Application | Laboratory |
| Product Type | Gravity |
| Display Type | Digital |
| Material | Stainless Steel |
| Color | Black |
| Display | 4 Digit 0.56” 7 segment Red LED display for Load (KN) 4 Digit 0.56” 7 segment Red LED display for Displacement (mm) |
| Range | Load: 1KN to Range Displacement: 0.1mm to 999.9 |
| Accuracy | ±0.1% of Full Scale ± 1 digit |
| Input | From 2 wire loop transmitter giving 4-20mA output, 4-20mA input => 0 – Range For displacement from 3 wire Rotary encoder (+5V pulses) |
| Relay Logic | Relay ON for 1. Load ≥ Set Load Limit 2. Displacement ≥ Set Displacement Limit 3. Load falling below Breaking Load after peaking |
| Normal/Peak Mode | Selectable from front panel with LED indication of mode |
| Peak Read | 9 peaks of both load and displacement with facility to reset memory |
| Peak Detection | Peak hold is resettable from front Reset Switch or by a rear external contact |
| Tare Facility (Zero) | Digital Tare using front panel Tare switch (for removing initial error). Tare also resets Displacement to Zero |
| Memory | Non-volatile EEPROM to save settings |
| Configuration Lock | On rear terminals to prevent unauthorized/accidental alteration of Range using front switches |
| Supply | 220V AC ± 15% 50/60Hz |
| Dimensions | Front Fascia: 96mm x 192mm Cut Out : 92mm x 188mm |
Additional Information:
View Complete details